防爆轴流风机配电机YBF8012 750W 2800R
防爆轴流风机配电机YBF8012 750W 2800R,对应的风机型号为BT35-11-3.55 2800R,以下为产品简介:
|
||||||||||
型号 |
功 率 |
电 压 |
频 率 |
电 流 |
转 速 |
效 率 |
功率因数 |
堵转转矩 |
堵转电流 |
较大转矩 |
|
W |
V |
Hz |
A |
r/min |
% |
COSQ |
额定转矩 |
额定电流 |
额定转矩 |
YBF6312 |
|
|
|
0.53 |
2800 |
69 |
0.75 |
|
|
|
YBF6322 |
|
|
|
0.68 |
|
72 |
0.78 |
|
|
|
YBF6314 |
|
380 |
50 |
0.48 |
1400 |
60 |
0.63 |
2.2 |
6 |
2.4 |
YBF6324 |
|
|
|
0.65 |
|
64 |
0.66 |
|
|
|
YBF7112 |
|
|
|
0.95 |
2800 |
75.5 |
0.8 |
|
|
|
YBF7122 |
550 |
|
|
1.35 |
|
73.5 |
0.82 |
|
|
|
YBF7114 |
250 |
|
|
0.83 |
1400 |
67 |
0.68 |
|
|
|
YBF7124 |
370 |
|
|
1.12 |
|
69.5 |
0.72 |
|
|
|
YBF8012 |
750 |
|
|
1.75 |
2800 |
76.5 |
0.85 |
|
|
|
YBF8022 |
1100 |
|
|
2.55 |
|
77 |
0.85 |
|
7 |
|
YBF8014 |
550 |
|
|
1.55 |
1400 |
73.5 |
0.73 |
|
6 |
|
YBF8024 |
750 |
|
|
2.01 |
|
75.5 |
0.75 |
|
6 |
|
YBF90S2 |
370 |
|
|
3.42 |
2800 |
78 |
0.85 |
|
7 |
|
YBF90L2 |
2200 |
|
|
4.7 |
|
82 |
0.86 |
|
7 |
|
YBF90S4 |
1100 |
|
|
2.71 |
1400 |
75.5 |
0.8 |
|
6.5 |
|
YBF90L4 |
1500 |
|
|
3.74 |
|
78.5 |
0.82 |
|
6.5 |
风机维护和储存:
1 使用环境应保持整洁,风机表面保持清洁,进、出风口不应有杂物。定期消除风机及管内的灰尘等杂物。
2 只能在风机完全正常情况下方可运行,同时要保持供电设施容量充足,电压稳定,严禁缺相运行,供电线路必须为**线路,不应长期使用临时线路供电。
3 风机在运行过程中发现有异响、电机严重发热、外壳带电、开关跳闸、不能启动等现象,应立即停机检查。为了保证安全,不允许在风机运行中维修。
4 根据使用环境条件不定期对轴承补充或更换润滑机油(电机封闭轴承在使用寿命内不必更换机油),为保证风机在运行过程中良好的润滑,加油次数不少于1000小时/次。
5 风机应储存在干燥的环境中,避免电机受潮,风机在露天存放时,应有防雨措施,在储存与搬运过程中应防止风机磕碰,以免风机收到损伤。
特别注意事项:
1 风机外壳或电机外壳的接地必须可靠;
2 禁止反方向旋转,禁止**额定电流运行,禁止缺相运行;
3 禁止在风机运转中进行维护。